Offices, people, and code · guide
ADA ramp length: the guide
An accessible ramp is 1 foot of run for every inch of rise, 30 inches of rise at most between 5-foot landings, and it gets long fast; the switchback is how it fits.
Why this number matters
The ADA Standards set a running slope of 1:12 for new ramps, which is 8.33%, with a landing at the top, the bottom, and every 30 inches of rise, each landing at least 60 inches long and 60 by 60 where the ramp turns. The clear width is 36 inches, handrails on both sides are required when the rise is over 6 inches, and edge protection keeps a wheel from leaving the surface. A 30-inch rise is 30 feet of ramp plus two landings, 40 feet in all; a 48-inch dock is two runs and three landings, over 60 feet straight.
Gentler slopes are kinder: 1:16 is easier for a manual chair and 1:20 is no longer a ramp at all and needs no handrails or landings, at the cost of length. The switchback layout folds the runs beside each other and is the usual answer where the straight run would not fit.
For a loading dock the ramp is rarely the answer; a vertical platform lift takes a fraction of the space, and the forklift ramp calculator covers the grades that matter for freight.
How it is figured
- ADA Standards 405: running slope 1:12 maximum, rise per run 30 in. maximum, landings 60 in. long at top, bottom, and between runs (60 by 60 where the ramp turns), 36 in. clear width, handrails both sides when the rise exceeds 6 in., edge protection.
- Run = rise × slope ratio; total = run + landings.
A worked example
A 30-inch rise at 1:12 is a 360-inch run in one segment with a top and bottom landing, 480 inches overall, 40 feet; a 48-inch rise needs two runs, three landings, and about 63 feet straight or a 34-foot switchback.
The tool's starting values, and what it returns for them:
| Rise | 30 in |
| Slope | 1:12 (8.33%), the ADA maximum for new work |
| Layout | Straight |
| Ramp run | 360 in |
| Total length with landings | 480 in |
| Runs | 1 |
| Footprint, straight | 40'-0" x 5'-0" |
| Grade | 8.33 % |
| Angle | 4.8 ° |
Mistakes that catch people
- Forgetting the landings, which add 10 to 15 feet.
- A 1:12 ramp with no handrails because it is 'short'.
- Cross slope over 2%, which the standard also limits.
Rules of thumb
- 1:12 maximum, 30 inches of rise per run, 60-inch landings.
- Handrails both sides over 6 inches of rise; 36-inch clear width.
- 1:20 or flatter is not a ramp.
When to stop calculating and make a call
- Public accommodations and new construction: the code official and the ADA Standards; local codes may be stricter.
- Existing buildings with no room: the standard has alternatives (1:10 and 1:8 for short rises in alterations) with conditions.
Questions people ask
- How long is a ramp for a 48-inch dock?
- 48 ft of ramp at 1:12 in two runs with three landings, about 63 ft overall straight, or a switchback about 34 ft long and 9 ft wide. For a dock, a lift is usually the better answer; the ramp calculator covers forklift grades.
Standards and sources
- 2010 ADA Standards for Accessible Design, 405 Ramps, 505 Handrails
This guide and the tool are planning aids. The equipment maker, the engineer of record, the accountant, or the code official confirms the final number for your building.