- ADA Standards 405: running slope 1:12 maximum, rise per run 30 in. maximum, landings 60 in. long at top, bottom, and between runs (60 by 60 where the ramp turns), 36 in. clear width, handrails both sides when the rise exceeds 6 in., edge protection.
- Run = rise × slope ratio; total = run + landings.
Need it quoted?
In-plant offices sized to the headcount, pre-wired, with HVAC and restrooms, priced as line items.
Modular officesADA ramp length
Ramp run
360 in
30'-0"
Total length with landings
480 in
40'-0" straight
Runs
1
2 landings of 60 in., max 30 in. rise per run
- Footprint, straight
- 40'-0" x 5'-0"36 in. clear width plus handrails and edge protection
- Grade
- 8.33 %
- Angle
- 4.8 °
One line for the file or the vendor
30" rise at 1:12: 30'-0" of ramp in 1 run(s), 2 landings, 40'-0" overall straight; handrails both sides.
How it is figured
- ADA Standards 405: running slope 1:12 maximum, rise per run 30 in. maximum, landings 60 in. long at top, bottom, and between runs (60 by 60 where the ramp turns), 36 in. clear width, handrails both sides when the rise exceeds 6 in., edge protection.
- Run = rise × slope ratio; total = run + landings.
Sources: 2010 ADA Standards for Accessible Design, 405 Ramps, 505 Handrails. A planning calculator; the maker, the engineer of record, or the code official confirms the final number.
Questions people ask
- How long is a ramp for a 48-inch dock?
- 48 ft of ramp at 1:12 in two runs with three landings, about 63 ft overall straight, or a switchback about 34 ft long and 9 ft wide. For a dock, a lift is usually the better answer; the ramp calculator covers forklift grades.
Related calculators: Forklift ramp grade, Stair rise and run, Occupant load and exits. All calculators.