Line Item SupplyIndustrial Equipment
Request a Quote

Offices, people, and code

Stair rise and run for a mezzanine

Floor-to-floor height and the code the stair falls under in; the riser count and height, the tread, the total run, the stringer length, and the landings.

Read the guide: what the number means and how to use it

  • Risers = total rise ÷ the maximum riser, rounded up, all equal. IBC 1011.5: riser 4 to 7 in., tread 11 in. minimum; the 25 in. rule (riser + tread about 17 to 18) sets a comfortable tread. OSHA 1910.25: riser 9.5 in. max, tread 9.5 in. min, 30 to 50° pitch.
  • Run = treads × tread depth; stringer = √(rise² + run²). Landings every 12 ft of vertical rise (IBC 1011.8).

Need it quoted?

In-plant offices sized to the headcount, pre-wired, with HVAC and restrooms, priced as line items.

Modular offices

Stair rise and run

21 risers at 6.86" · 20 treads at 11.0"

Risers

21

6.86 in. each

Total run

220 in

20 treads at 11 in., 18'-4"

Stringer length

263 in

21'-11", 32° pitch

Riser height
6.86 in
Tread depth
11 in
Intermediate landings
0none needed under 12 ft of rise
Footprint with a bottom landing
22'-0" long x 3'-8" wide

One line for the file or the vendor

12'-0" rise, IBC: 21 risers at 6.86", 20 treads at 11", run 18'-4", stringer 21'-11", 0 landing(s), 44" wide.

Keep this result, or have it priced

One email with what you asked for. No list, no newsletter.

How it is figured

  • Risers = total rise ÷ the maximum riser, rounded up, all equal. IBC 1011.5: riser 4 to 7 in., tread 11 in. minimum; the 25 in. rule (riser + tread about 17 to 18) sets a comfortable tread. OSHA 1910.25: riser 9.5 in. max, tread 9.5 in. min, 30 to 50° pitch.
  • Run = treads × tread depth; stringer = √(rise² + run²). Landings every 12 ft of vertical rise (IBC 1011.8).

Sources: IBC 2021 Section 1011 (stairways); OSHA 29 CFR 1910.25 (stairways, standard, ship, and alternating tread). A planning calculator; the maker, the engineer of record, or the code official confirms the final number.

Questions people ask

IBC or OSHA for a mezzanine stair?
If the mezzanine is a required exit path or is open to employees generally, the building code (IBC) governs and the official inspects to it; OSHA's 9.5 in. riser applies to stairs serving equipment and maintenance. Most mezzanine makers quote IBC stairs and OSHA only where the customer confirms it.

Related calculators: Mezzanine floor and column loads, Guardrail take-off, Occupant load and exits. All calculators.