Line Item SupplyIndustrial Equipment
Request a Quote

Energy and payback

Air compressor size for a shop

The tools and how hard they run, leaks, and growth in; the cfm the compressor needs, the horsepower, and the receiver tank.

Read the guide: what the number means and how to use it

  • Average demand = continuous cfm + intermittent cfm × duty cycle. Compressor delivery = demand × leak allowance × growth. Horsepower at about 4 cfm per hp (rotary screw at 100 psig; reciprocating 3 to 3.5).
  • Receiver: 3 gallons per cfm of compressor capacity carries the peaks of intermittent tools; larger where many tools start together.

Need it quoted?

See what the first-year deduction does to the payback on the same purchase.

Section 179

Air compressor sizing

100 psi52cfm needed

Compressor delivery needed

52 cfm

at 100 psig

Compressor

15 hp

about 4 cfm per hp at 100 psig

Receiver tank

160 gal

about 3 gallons per cfm for intermittent loads

Average demand
38 cfm
Peak if every tool runs at once
80 cfm

One line for the file or the vendor

20 cfm continuous + 60 cfm intermittent at 30% duty, 15% leaks, 20% growth: 52 cfm, 15 hp, 160 gal receiver at 100 psig.

Keep this result, or have it priced

One email with what you asked for. No list, no newsletter.

How it is figured

  • Average demand = continuous cfm + intermittent cfm × duty cycle. Compressor delivery = demand × leak allowance × growth. Horsepower at about 4 cfm per hp (rotary screw at 100 psig; reciprocating 3 to 3.5).
  • Receiver: 3 gallons per cfm of compressor capacity carries the peaks of intermittent tools; larger where many tools start together.

Sources: Compressed Air and Gas Institute (CAGI), Compressed Air and Gas Handbook; Compressor manufacturer sizing guides (Quincy, Ingersoll Rand, Sullair). A planning calculator; the maker, the engineer of record, or the code official confirms the final number.

Questions people ask

What size compressor for a dock and shop?
A dock with air-powered levelers and a few impact tools runs on a 10 to 15 hp rotary screw, 40 to 60 cfm. A body shop with sanders and paint runs 25 to 30 hp. Oversizing wastes power at part load unless the compressor has a VFD.

Related calculators: Compressed air leak cost, Electricity cost, Breaker size. All calculators.