Air compressor sizing: the guide

A compressor is sized on the air the tools actually use, continuous loads plus intermittent ones at their duty cycle, with leaks and growth on top, and the receiver carries the peaks.

Open the calculator

Why this number matters

Adding up the rated cfm of every tool oversizes the compressor by two or three times, because impact wrenches and grinders run a third of the time. The method is continuous loads at their full cfm, intermittent tools at their rated cfm times the fraction of the time they run, plus an allowance for leaks and for the next tool, which lands the compressor near its sweet spot rather than cycling at 30% load.

Horsepower follows at about 4 cfm per hp at 100 psig for a rotary screw, 3 to 3.5 for a reciprocating unit, and the receiver at about 3 gallons per cfm carries the few seconds when every tool starts at once. A variable speed drive on the compressor turns part load from a waste into a saving, which matters because few plants run at the design load for long.

Pressure sets the energy: tools want 90 psi at the inlet, so a header at 100 to 110 with good piping is enough, and every bar above that is paid for forever.

How it is figured

  • Average demand = continuous cfm + intermittent cfm × duty cycle. Compressor delivery = demand × leak allowance × growth. Horsepower at about 4 cfm per hp (rotary screw at 100 psig; reciprocating 3 to 3.5).
  • Receiver: 3 gallons per cfm of compressor capacity carries the peaks of intermittent tools; larger where many tools start together.

A worked example

Twenty cfm of continuous equipment and 60 cfm of intermittent tools at 30% duty is 38 cfm of demand; with 15% for leaks and 20% growth that is 52 cfm, a 15 hp compressor, and a 160-gallon receiver.

The tool's starting values, and what it returns for them:

Continuous tools and equipment20 cfm
Intermittent tools, rated cfm added up60 cfm
Duty cycle of the intermittent tools30 %
Leak allowance15 %
Growth20 %
Pressure100 psig
Compressor delivery needed52 cfm
Compressor15 hp
Receiver tank160 gal
Average demand38 cfm
Peak if every tool runs at once80 cfm

Mistakes that catch people

  • Summing tool ratings.
  • A compressor sized for the day the whole shop runs at once, cycling the other 364.
  • No receiver, so the compressor starts every time a nailer fires.

Rules of thumb

  • 4 cfm per hp at 100 psig (screw); 3 to 3.5 (recip).
  • Intermittent tools at 25 to 40% duty.
  • Receiver 3 gallons per cfm; more where tools start together.

When to stop calculating and make a call

  • Over about 50 hp, multiple compressors, or dryers and filtration for paint or instrumentation: a compressed air system design.
  • Dock equipment on air: the leveler maker's cfm at the pit is the continuous load to count.

Questions people ask

What size compressor for a dock and shop?
A dock with air-powered levelers and a few impact tools runs on a 10 to 15 hp rotary screw, 40 to 60 cfm. A body shop with sanders and paint runs 25 to 30 hp. Oversizing wastes power at part load unless the compressor has a VFD.

Standards and sources

  • Compressed Air and Gas Institute (CAGI), Compressed Air and Gas Handbook
  • Compressor manufacturer sizing guides (Quincy, Ingersoll Rand, Sullair)

This guide and the tool are planning aids. The equipment maker, the engineer of record, the accountant, or the code official confirms the final number for your building.