Read the guide: what the number means and how to use it

  • With clean supply air the count decays exponentially: C(t) = C0 × e^(−ACH × t / 60). Time to a target = ln(C0 ÷ C1) ÷ (ACH ÷ 60), multiplied by a mixing factor because a turbulent room does not dilute as evenly as the ideal; 100:1 recovery (ISO 14644-3 B.12) is ln(100) ÷ the decay rate.

Need it quoted?

See what the first-year deduction does to the payback on the same purchase.

Section 179

Cleanroom recovery time

0 min30 min3.5 minminutes to recover

Time to recover

3.5 min

5.7:1 down to the target

100:1 recovery time

9.2 min

the ISO 14644-3 test figure

Count halves every

1.39 min

Dilution ratio
5.7

One line for the file or the vendor

45 ACH, 2,000,000 down to 352,000/m³, mixing 1.5: 3.5 min; 100:1 recovery 9.2 min.

Keep this result, or have it priced

One email with what you asked for. No list, no newsletter.

How it is figured

  • With clean supply air the count decays exponentially: C(t) = C0 × e^(−ACH × t / 60). Time to a target = ln(C0 ÷ C1) ÷ (ACH ÷ 60), multiplied by a mixing factor because a turbulent room does not dilute as evenly as the ideal; 100:1 recovery (ISO 14644-3 B.12) is ln(100) ÷ the decay rate.

Sources: ISO 14644-3:2019, Test methods, Annex B recovery test; IEST-RP-CC012, cleanroom design (recovery and air change). A planning calculator; the maker, the engineer of record, or the code official confirms the final number.