Line Item SupplyIndustrial Equipment
Request a Quote

Material handling and racking

Pallet rack beam and upright loads

Pallets per level, pallet weight, levels, and the beam rating in; the load on each beam pair, the load on the frame, and the slab pressure under the base plate.

Read the guide: what the number means and how to use it

  • Beam pair load = pallets per level × the heaviest pallet, compared with the beam pair's rated capacity (uniformly distributed, from the beam stamp or the maker's table).
  • Frame load = beam level load × levels for an interior frame (it carries half of each bay beside it, which adds to one bay) and half that for an end frame; each post takes half the frame. Base plate pressure = post load ÷ plate area.

Need it quoted?

Guardrail, bollards, rack protection, and mezzanines priced as line items.

Guardrail and protection

Pallet rack beam and frame loads

per pallet 2,200 lbbeam pair 4,400 lbrated 5,000 lbupright 13,200 lb

Load on each beam pair

4,400 lb

within the 5,000 lb rating

Load on the frame

13,200 lb

interior frame, half of each adjacent bay

Pressure under each base plate

138 psi

  • 138 psi under the base plate is high for a plain slab; the rack maker's frame table and a slab check by an engineer are needed before loading.
Load in one bay above the floor
13,200 lb
Load on each post
6,600 lb

One line for the file or the vendor

2 pallets x 2200 lb x 3 levels: 4400 lb per beam pair (rated 5000), frame 13200 lb, 138 psi on a 48 sq in base plate.

Keep this result, or have it priced

One email with what you asked for. No list, no newsletter.

How it is figured

  • Beam pair load = pallets per level × the heaviest pallet, compared with the beam pair's rated capacity (uniformly distributed, from the beam stamp or the maker's table).
  • Frame load = beam level load × levels for an interior frame (it carries half of each bay beside it, which adds to one bay) and half that for an end frame; each post takes half the frame. Base plate pressure = post load ÷ plate area.
  • The frame's own capacity depends on its height to the first beam and the column section (RMI tables); this calculator gives the demand, the maker's table gives the capacity.

Sources: ANSI MH16.1 / RMI, Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks; Rack manufacturer beam and frame capacity tables. A planning calculator; the maker, the engineer of record, or the code official confirms the final number.

Questions people ask

What does a beam rating mean?
The load a pair of beams carries spread evenly along them, per level. Two 2,200 lb pallets on a pair rated 5,000 lb is fine; a 4,000 lb coil sitting in the middle of the beams is a point load and takes a heavier beam even though it is under 5,000.

Related calculators: Pallet positions, Mezzanine floor and column loads, Forklift aisle width. All calculators.