Metal buildings and structure · guide
Gutter and downspout sizing: the guide
Gutters overflow in the cloudburst, not the average rain, so they are sized to the five-minute hundred-year intensity for the site, and downspouts are the usual shortfall.
Why this number matters
A gutter carries the water from the roof area that drains to it, and the flow is that area times the rainfall rate. The rate that matters is the worst five minutes in a hundred years, about 6 inches an hour in Michigan and 8 in the Gulf states, because a gutter that cannot keep up for five minutes overflows behind the fascia and into the wall. Steep roofs shed water faster, which SMACNA handles with a pitch factor on the area.
Downspouts are sized by the square inches of leader per square foot of roof, about one square inch per hundred square feet at an inch an hour, scaled by the intensity. A 3 by 4 downspout handles about 600 square feet in a 1-inch rain and 100 in a 6-inch one, which is why long metal building eaves with downspouts every 60 feet overflow in a storm. Two per gutter minimum and never more than 50 feet apart is the practical rule.
On metal buildings the gutter is usually a box gutter from the building maker; the sizing still applies, and the calculator's output is the check on the downspout count on the drawings.
How it is figured
- Drained area = eave length × slope length × a pitch factor (SMACNA: 1.0 up to 3:12, up to 1.3 at 12:12). Flow = area × rainfall ÷ 96.23 gpm.
- Downspouts: one square inch of leader drains about 100 sq ft of roof at 1 in/hr (SMACNA), scaled by the intensity; at least two per gutter and not over 50 ft apart. Gutter size from the SMACNA half-round capacities with a K-style and box gutter allowance of about 1.5 times.
A worked example
A 120-foot eave draining a 42-foot slope is 5,040 square feet; at 3 inches an hour that is 157 gallons a minute into a 6-inch gutter, and 4 by 4 downspouts handle 400 square feet each at that rate, so 13 of them, about one every 9 feet, or larger leaders at wider spacing.
The tool's starting values, and what it returns for them:
| Eave length on this gutter | 120 ft |
| Roof slope length, eave to ridge | 42 ft |
| Roof pitch | 1 :12 |
| Rainfall intensity | 3 in per hour |
| Downspout | 4 x 4 in. or 4 in. round (12 sq in) |
| Gutter | 5 in. K-style or box |
| Downspouts | 13 |
| Flow at the design rain | 157 gpm |
| Drained area, adjusted for pitch | 5,040 sq ft |
| Downspout spacing | 9 ft |
Mistakes that catch people
- Sizing to the hourly average rainfall instead of the five-minute intensity.
- One downspout at each end of a 150-foot gutter.
- Forgetting that a parapet or a higher roof adds its area to the low gutter.
Rules of thumb
- Five-minute, 100-year rain: Great Lakes about 6 in/hr, South 7 to 8, Northwest 3.
- One square inch of downspout per 100 square feet at 1 in/hr; divide by the intensity.
- Downspouts no more than 50 feet apart.
When to stop calculating and make a call
- Internal roof drains and overflow scuppers: the plumbing code and a plumbing engineer.
- Snow country: snow guards, heat trace, and gutter loading are their own design.
Questions people ask
- What rainfall rate do I use?
- The 100-year, 5-minute intensity for the site, which is what gutters are sized to since they overflow in a cloudburst, not over an hour. The IPC appendix lists it by city: Detroit about 6.3, Dallas 8.0, Miami 8.6, Seattle 2.7 in/hr.
Standards and sources
- SMACNA Architectural Sheet Metal Manual, gutters and downspouts (Tables 1-1 to 1-3)
- International Plumbing Code, Chapter 11 and Appendix B (rainfall rates)
This guide and the tool are planning aids. The equipment maker, the engineer of record, the accountant, or the code official confirms the final number for your building.