Metal buildings and structure
Gutter and downspout size for a roof
Roof area draining to one gutter, the pitch, and the local rainfall in; the gutter size, the downspouts, and the spacing.
Read the guide: what the number means and how to use it
- Drained area = eave length × slope length × a pitch factor (SMACNA: 1.0 up to 3:12, up to 1.3 at 12:12). Flow = area × rainfall ÷ 96.23 gpm.
- Downspouts: one square inch of leader drains about 100 sq ft of roof at 1 in/hr (SMACNA), scaled by the intensity; at least two per gutter and not over 50 ft apart. Gutter size from the SMACNA half-round capacities with a K-style and box gutter allowance of about 1.5 times.
Need it quoted?
Send the footprint, eave height, and openings and the quotation comes back with frames, sheeting, trim, insulation, and doors as line items.
Metal buildingsGutter and downspout sizing
Gutter
5 in. K-style or box
Downspouts
13
12 sq in each, every 9 ft
Flow at the design rain
157 gpm
- Drained area, adjusted for pitch
- 5,040 sq ft
- Downspout spacing
- 9 ft
One line for the file or the vendor
120 ft eave, 42 ft slope at 1:12, 3 in/h: 5040 sq ft drained, 157 gpm, 5 in. gutter, 13 downspouts (12 sq in) every 9 ft.
How it is figured
- Drained area = eave length × slope length × a pitch factor (SMACNA: 1.0 up to 3:12, up to 1.3 at 12:12). Flow = area × rainfall ÷ 96.23 gpm.
- Downspouts: one square inch of leader drains about 100 sq ft of roof at 1 in/hr (SMACNA), scaled by the intensity; at least two per gutter and not over 50 ft apart. Gutter size from the SMACNA half-round capacities with a K-style and box gutter allowance of about 1.5 times.
Sources: SMACNA Architectural Sheet Metal Manual, gutters and downspouts (Tables 1-1 to 1-3); International Plumbing Code, Chapter 11 and Appendix B (rainfall rates). A planning calculator; the maker, the engineer of record, or the code official confirms the final number.
Questions people ask
- What rainfall rate do I use?
- The 100-year, 5-minute intensity for the site, which is what gutters are sized to since they overflow in a cloudburst, not over an hour. The IPC appendix lists it by city: Detroit about 6.3, Dallas 8.0, Miami 8.6, Seattle 2.7 in/hr.
Related calculators: Roof pitch converter, Metal building sheeting take-off, Roof snow load. All calculators.