Line Item SupplyIndustrial Equipment
Request a Quote

Metal buildings and structure

Roof snow load from the ground snow load

Ground snow load, exposure, thermal condition, and importance in; the flat-roof snow load the frames are designed for, by the ASCE 7 method, with the low-slope minimum.

Read the guide: what the number means and how to use it

  • ASCE 7-16 Section 7.3: flat roof snow load pf = 0.7 × Ce × Ct × Is × pg.
  • Section 7.3.4 minimum for low-slope roofs: pm = Is × pg where pg is 20 psf or less, otherwise 20 × Is. The design value is the larger. Sloped roof, drift, sliding, and unbalanced loads are applied by the engineer on top.

Need it quoted?

Send the footprint, eave height, and openings and the quotation comes back with frames, sheeting, trim, insulation, and doors as line items.

Metal buildings

Roof snow load

80 ft wide · 20 ft eave · 1:12roof snow 21 psf

Flat roof snow load

21 psf

0.7 × 1 × 1 × 1 × 30

Low-slope minimum

20 psf

applies to roofs under about 15° (3:12)

Design roof snow load

21 psf

the larger of the two, before drift and slope factors

  • Under 3:12 the low-slope minimum governs where it is larger, and drifts against parapets, equipment, and taller walls add to it; the building's engineer applies those.
Snow depth that weighs this much
1.4 ftat 15 lb per cu ft, a settled snow

One line for the file or the vendor

pg 30 psf, Ce 1, Ct 1, Is 1: flat roof snow 21 psf, minimum 20 psf, design 21 psf.

Keep this result, or have it priced

One email with what you asked for. No list, no newsletter.

How it is figured

  • ASCE 7-16 Section 7.3: flat roof snow load pf = 0.7 × Ce × Ct × Is × pg.
  • Section 7.3.4 minimum for low-slope roofs: pm = Is × pg where pg is 20 psf or less, otherwise 20 × Is. The design value is the larger. Sloped roof, drift, sliding, and unbalanced loads are applied by the engineer on top.

Sources: ASCE 7-16, Chapter 7, Snow Loads (7.3, 7.3.4, Tables 7.3-1 to 7.3-3); MBMA Metal Building Systems Manual, Section 1 (loads). A planning calculator; the maker, the engineer of record, or the code official confirms the final number.

Questions people ask

Where do I find the ground snow load?
The ASCE 7 snow map (Figure 7.2-1) or the ASCE Hazard Tool by address, and the local building department, which may set a higher value in snow country. The building quote should state the ground snow load it was designed for.
Why is the roof load less than the ground load?
Wind blows snow off a roof and heat from below melts some of it, which the 0.7 factor and the exposure and thermal factors account for. An unheated, sheltered building gets most of the ground load; a cold storage roof gets more than the ground load.

Related calculators: Metal building sheeting take-off, R-value and heat loss, Roof pitch converter. All calculators.