Pre-engineered metal buildings: the rigid-frame package.

A pre-engineered metal building is designed as one system by the manufacturer's engineers, for the exact loads at your address. Welded rigid frames carry the building; cold-formed purlins and girts carry the panels. It is the standard way to build a plant, a warehouse, or a large shop in steel.

Cutaway drawing of a clear-span metal building interior with tapered rigid frames and no interior columns

Representative drawing of the equipment type, not the exact configuration quoted.

How a PEMB is built

The primary frames are built up from welded steel plate. Columns and rafters are usually tapered, deeper where the bending is greatest and shallower where it is not, which puts the steel where the loads need it. The frames bolt together on site at the knees and the ridge.

Between the frames run the secondary members: Z-shaped purlins on the roof, girts on the walls, and an eave strut where they meet. Rod or cable bracing, or portal frames, resists wind along the length of the building. Roof and wall panels screw to the secondary framing and complete the structure.

  • Clear-span frames leave the whole floor open, with no interior columns
  • Modular frames add interior columns to cover very wide buildings economically
  • Single-slope and lean-to frames handle additions and canopies
  • Frames can be designed for bridge cranes, mezzanines, and rooftop equipment
Isometric drawing of a steel building frame being erected with a crane on site

Representative drawing of the equipment type, not the exact configuration quoted.

When a PEMB is the right system

Choose a rigid-frame building when the span is wide, the eave is tall, or the building has to carry more than its own roof. Overhead cranes, heavy collateral loads, large framed openings, and future expansion are all handled in the frame design. The endwall can be built as an expandable frame so the building can be lengthened later without rework.

What we need to quote it

Send the dimensions and the site, and we return a quotation for the package with the drawings and freight to the job site.

  • Width, length, eave height, and roof slope
  • Job site address, for snow, wind, and seismic loads
  • Use of the building and whether it is heated
  • Doors, windows, and framed openings with sizes and locations
  • Cranes, mezzanines, sprinklers, rooftop units, or anything else the frames carry
  • Roof and wall panel preference, colors, and insulation if you want it in the package

Questions

Is a PEMB the same as a red iron building?
Usually, yes. Red iron is the trade name for the red oxide primer on the welded frames of a pre-engineered metal building. The primer is a shop coat for protection during shipping and erection, not a finish.
Can a PEMB carry an overhead crane?
Yes, when the crane is known before the building is engineered. The crane capacity, span, hook height, and class of service are design inputs, and the frames and columns are sized for them. Adding a crane to a building that was not designed for one is a separate engineering job.
Can the building be expanded later?
Lengthening is straightforward when the endwall was ordered as an expandable frame. Widening is done with a lean-to or a second building beside the first. Tell us about likely expansion so the first building is designed for it.