Line Item SupplyIndustrial Equipment
Request a Quote

Applications

Air curtains: a wall of air across the door that has to stay open.

Some doors cannot close. A receiving door during a delivery, a cooler door during stocking, a walkway door into the plant, a customer entrance in a hot or cold climate. An air curtain mounts above the opening and blows a stream of air down across it, pushing back the outside air, the dust, the flies, and most of the heat exchange while the door is open.

It is a modest purchase that shows up in three places: the energy bill, the pest control audit, and the comfort of the people who work next to the door.

Isometric drawing of a building with two insulated sectional overhead doors, a walk door, and bollards

Representative drawing of the equipment type, not the exact configuration quoted.

Reviewed November 4, 2026. Official sources are linked where they exist.

Short answer

An industrial air curtain is a fan unit mounted above a door that blows a controlled stream of air down across the opening. It works where a door has to stay open: receiving and dock doors during deliveries, cooler and freezer doors during stocking, walk doors between the plant and the outside, and customer entrances. It is sized by the door's width and height, with enough velocity to reach the floor, and by whether it is heated. In food plants it is a standard pest control measure that auditors look for. We quote units by the opening, with mounting, controls, and heating as line items, from a photo of the door and its dimensions, and installation on the same quotation when you want it.

What this facility buys from us

How it works and what it does not do

The air stream is a barrier with some leakage. A properly sized unit stops most insects, dust, and heat exchange across an open door; it does not seal the opening the way a closed door does. The right picture is an air curtain for the time the door is open and a good door for the rest. Sized too small, the stream breaks up before the floor and the barrier opens at the bottom; mounted with a gap above the door, outside air slips over the top.

Where it pays

The applications where the purchase shows a return.

  • Receiving and shipping doors that stay open during loading, in summer heat and winter cold
  • Cooler and freezer doors during stocking, when the door is propped open by the cart
  • Doors between a conditioned plant and an unconditioned warehouse
  • Food, beverage, and pharmaceutical plants, where pest exclusion is audited
  • Customer and employee entrances in hot or cold climates, for comfort and HVAC load
  • Drive-through and pickup windows that open constantly

Sizing

The door decides the unit.

Air curtain sizing factors
WidthThe unit or units must cover the full width of the opening with a small overlap; multiple units for wide dock doors
HeightMounting height sets the required air velocity; a 14 foot door needs a stronger unit than an 8 foot door for the stream to reach the floor
ExposureWind and the pressure difference across the door (stack effect, exhaust fans) push the stream; exposed doors need more velocity
Heated or unheatedElectric, hot water, or steam heat for comfort at an entrance; unheated for a dock or a cooler door
MountingInside above the door is standard; recessed or outside mounts for low headroom; cooler doors often mount outside the cold side
ControlsA door switch so the unit runs only when the door is open, a thermostat for heated units, and a speed control for exposure
DutyWashdown and corrosion-resistant units for food plants; industrial-grade motors for doors that cycle all day

Air curtains and doors together

At a dock door the air curtain runs while the door is open and the dock seal closes the gap around the trailer. At a cooler door the high-speed door handles the forklift cycles and the air curtain covers the stocking period when the door stays open. We quote the door, the seal, and the air curtain as one package at the opening so the controls work together.

What to send

A photo of the door from the inside and three numbers.

  • Door width and height, and the headroom above the opening
  • What the door opens to: outside, a cooler, a freezer, another building
  • Heated or unheated, and the power available at the door
  • How long the door stays open and how often
  • Exposure: prevailing wind, exhaust fans, and whether the building is pressurized

Questions buyers ask

Will an air curtain keep flies out of a food plant?
It reduces insect entry substantially when sized to the opening and mounted correctly, and auditors look for it at doors that stay open. It works with sealed docks, door sweeps, and a pest control program, not instead of them.
Does an air curtain replace a door?
No. It covers the time the door is open. A closed door seals; an air curtain reduces exchange.
Heated or unheated?
Heated for entrances where people stand near the door in winter; unheated for docks, coolers, and plant doors where the goal is a barrier, not comfort.
Can one unit cover a 12 foot dock door?
Often two units side by side, or one long unit, depending on the product line; the quotation shows the arrangement.
Can installation be on the quotation?
Yes. Tick "Quote installation too" and an installer from our network mounts and wires it, often with the door at the same opening.

Do your own research

Official sources first. We link the rule, not a summary of the rule, wherever one exists.